APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4305 Issued:1980-03-19
Revised:2012-07-21
Style 4305 Parallel cable with extruded integral insulation and jacket

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor30-16 AWG solid or stranded, tinned or bare copper.
InsulationLabeled or complying with manufactuer's AWM procedure, Style 1672.
AssemblyWires in Sizes 30-16 AWG may be used in cables consisting of from 2 to 100 conductors bonded together in such a fashion to form a flat ribbon-type cable. All conductors in any one cable may be of the same AWG size or mixed AWG sizes. Similar cables may be formed from twisted pairs bonded together in a 2-100 conductor assembly.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances and electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024