APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4309 Issued:1980-05-27
Revised:2019-11-12
Style 4309 Multiple-conductor cable using non-integral jacket

Rating80 deg C, voltage not specified, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded.
InsulationExtruded XLPVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
AssemblyTwo to twenty
ShieldOptional on one or more conductors.
BraidOptional.
JacketExtruded XLPVC
dia of cable under jacket
0.350 inches or less8 mils minimum average thickness6 mils minimum thickness at any point
0.351 or 0.700 dia15 avg13 minimum
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment where not exposed to movement or mechanical abuse.

UL and the UL Logo are trademarks of UL LLC © 2024