APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4311 Issued:1980-06-11
Revised:2012-04-02
Style 4311 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating125 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying Manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and is applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
CoveringOptional. An XLPE covering may be extruded over the conductor assembly, having minimum thickness of 10 mils.
JacketExtruded XLPE
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
1.000 or less3024
1.001-1.5004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.