Rating | 125 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complying Manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and is applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Covering | Optional. Extruded XLPE covering having a minimum thickness of 10 mils, may be employed over the conductor assembly. |
|
Braid | Optional. |
|
Jacket | Extruded XLPE |
| Diameter of core assembly under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnect of electronic equipment. |
|