APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4313 Issued:1980-06-11
Revised:2012-12-11
Style 4313 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating125 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying Manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, Nylon, oriented PET or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
CoveringOptional - Extruded XLPE, 10 mils minimum thickness at any point. May be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded XLPE
dia of cable under jacket is 0.425 inches or less45 mils min average36 mils min at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect of electronic equipment.