APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4324 Issued:1981-07-10
Revised:2011-12-02
Style 4324 Multiple-conductor cable using non-integral jacket.

Rating75 deg C, 600 Vac, FT2 flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo conductor cable may be flat or twisted. Three or more conductors shall be twisted. If more than one group is used, groups shall be twisted together. (The length of lay of the twisted conductors or groups is not specified). Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded Neoprene, If diameter of cable under jacket is 1.500 inches or less, 60 mils minimum average thickness, 48 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024