| Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
| Conductor | 40 AWG minimum, material not specified. |
|
| Insulation | Extruded PE, extruded FRPE, extruded foamed PE, extruded foamed FRPE, extruded XLPE or extruded foamed XLPE, 3 mils minimum thickness at any point. |
|
| Assembly | Two to 100 singles or group of singles twisted together. Barrier layer and/or fillers optional. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickenss at any point |
| 0.425 inches or less | 30 mils | 24 mils |
| 0.426-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal or external wiring. |
|