APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4327 Issued:1982-06-09
Revised:2008-05-27
Style 4327 Multiconductor cable with extruded non-integral jacket

Rating105 deg C, 300 Vac, VW-1 flame.
Conductor32 AWG - 16 AWG solid or stranded.
InsulationXLPVC, 15 mils minimum average, 13 mils minimum at any point.
AssemblyTwo to seven conductors
ShieldOptional on one or more conductors.
JacketXLPVC, 15 mils minimum average, 13 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Wiring of Audio Electronic Video or Equipment.