APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4328 Issued:1982-10-11
Revised:2012-05-14
Style 4328 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 300 Vac, FT2 Flame.
Conductor18 AWG - 10 AWG, Solid or Stranded Round.
InsulationExtruded CP or Extruded CPE or Extruded EP or Extruded NBR/PVC or Extruded Neoprene or Extruded SBR/NR or Extruded XL, 30 mils minimum average, 27 mils minimum at any point.
AssemblyTwo to twenty conductors, same as type SJO Cord. Mixed conductor sizes may be employed.
JacketExtruded CP or Extruded EPDM or Extruded NBR/PVC or Extruded Neoprene or Extruded SBR/NR
dia of cable under jacket inchesmils minimum averagemils minimum at any point
0.425 or less3024
0.426-0.7004536
0.701-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances or external interconnection in electric trucks or internal wiring of medical equipment or external interconnection of medical equipment.