Rating | 60 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. Material not specified. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional; manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. Extruded PVC, 5 mils minimum over singles or assembly. |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded EVA |
| dia of cable under jacket |
| 0.425 inches or less | 45 mils min average | 36 mils min at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | As internal wiring or external interconnection in Class 2 circuits of electronic equipment (such as computers and electric business machines). |
|