APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4334 Issued:1983-01-03
Revised:2012-04-10
Style 4334 Multiple conductor with extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG, solid or stranded.
InsulationExtruded XLPVC, 6 mils min average, 5 mils min at any point. Top or bottom layers may form ridges. Extruded or heat laminated PVC.
AssemblyTwo to 150 laid parallel with spaced 0.025 in. min between conductors. Top or bottom layers may form ridges. Extruded or heat laminated PVC.
ShieldOptional.
CoveringOptional. Extruded XLPVC, 5 mils min at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
Use"Internal wiring of Electronic Equipment" (such as computers and electric business machines).

UL and the UL Logo are trademarks of UL LLC © 2024