APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4342 Issued:1984-04-12
Revised:2012-04-02
Style 4342 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating90 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Cable may contain Labeled Flat Ribbon Style AWM which may be rolled or spiralled and formed around fillers or bunched singles. Fillers and/or tape wrap or extruded covering may be used.
ShieldOptional.
JacketExtruded XLCP
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
1.000 or less3024
1.001-1.500 dia4536
1.501-2.5006048
Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024