APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4344 Issued:1984-04-12
Revised:2012-05-15
Style 4344 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating90 deg C, 300 Vac, Cable flame.
Conductor32 AWG minimum, solid or stranded.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Cable may contain Labeled Flat Ribbon Style AWM which may be rolled or spiralled and formed around fillers or bunched singles. Fillers and/or tape wrap or extruded covering may be used.
ShieldOptional.
JacketExtruded CP
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701 - 1.000 inch60 mils48 mils
1.001 - 1.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: "600 Volts peak for Electronic Use Only".