APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4345 Issued:1984-04-23
Revised:2012-01-29
Style 4345 Parallel Cable with extruded integral insulation and jacket

Rating125 deg C, 600 Vac, Horizontal flame.
ConductorTwo, three or four No. 10 - 28 AWG solid or stranded, tinned or bare copper.
InsulationSimilar to Type SP except that the insulation is a nominal 1/32 in and the min acceptable thickness at any point before and after separation is 27 mils of EP rubber. Facing Page for Compound Identification.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment or appliances.