APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4350 Issued:1984-05-18
Revised:2012-04-23
Style 4350 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, no voltage assigned, Cable flame.
Conductor40 AWG minimum.
Insulated ConductorLabeled or complies with manufacturer's AWM Procedure rated 105°C minimum.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional, manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded Ethylene acrylic elastomer - See Facing Page for Compound
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch. or less45 mils36 mils
0.426-0.700 inch.60 mils48 mils
0.701-1.500 inch.80 mils64 mils
1.501-2.500 inch.110 mils88 mils
2.501 inch. and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection of electronic equipment (such as computer cable and business machines).