APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4352 Issued:1984-05-18
Revised:2019-11-07
Style 4352 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum. Material not specified.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional, manufacturer shall maintain a complete description of each assembly.
ShieldOptional - May be over one or more of the insulated conductors or applied over the assembly.
BraidOptional.
JacketExtruded EVA - See facing page for compound
dia of cable under jacket
0.425 or less in inches30 mils min average24 mils minimum at any point
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection in Class 2 circuits of electronic equipment (such as electronic computers and electric business machines.)