Rating | 105 deg C, 30 Vac, Horizontal flame or Cable flame. |
|
Conductor | 40 AWG minimum. Material not specified. |
|
Insulation | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional, manufacturer shall maintain a complete description of each assembly. |
|
Shield | May be over one or more of the insulated conductors or applied over the assembly. |
|
Braid | Optional. |
|
Jacket | Extruded EVA - See facing page for compound |
| dia of cable under jacket |
| 0.425 or less in inches | 30 mils minimum average thickness | 24 mils minimum thickness at any point |
| 0.426-0.700 dia | 45 avg | 36 min |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.000 1.500 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external wiring in Class 2 circuits. |
|