APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4354 Issued:1984-05-18
Revised:2014-06-20
Style 4354 Multiconductor cable with extruded non-integral jacket.

Rating105 deg C, voltage not specified, Cable flame.
Conductor40 AWG minimum. Material not specified.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded SR.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less45 mils36 mils
0.426-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.501 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external wire.