APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4356 Issued:1984-08-29
Revised:2012-10-24
Style 4356 Multi-conductor cable with non-integral jacket.

Rating80 deg C, voltage not spedified, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded.
InsulationExtruded XLPVC, 10 mils min average thickness, 8 mils minimum thickness at any point.
AssemblyTwo or three conductors.
ShieldOptional.
JacketExtruded PVC, 12 mils min average thickness, 10 mils minimum thickness at any point.
ShieldOptional.
JacketOptional - Extruded PVC, 12 mils min average thickness, 10 mils min thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment where not exposed to Movement or Mechanical Abuse.