APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4360 Issued:1985-04-02
Revised:2012-04-04
Style 4360 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyConsists of two or more conductors. Jacket has 0.5 inch maximum wide web.
JacketExtruded XLPO, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024