| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 32 AWG - 16 AWG, solid or stranded. |
|
| Insulation | Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Assembly | Consists of two or more conductors. Jacket has 0.5 inch maximum wide web. |
|
| Jacket | Extruded XLPO, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|