APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4369 Issued:1987-01-09
Revised:2012-04-24
Style 4369 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 300 Vac, FT2 flame.
Conductor10 AWG stranded.
InsulationExtruded EP, 45 mils minimum average thickness, 40 mils minimum thickness at any point.
AssemblyThree, same as type HSJO Cord
JacketEstruded EPDM, 60 mils minimum average thickness, 48 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of heating appliances where the acceptability of the combination, including the current-carrying capacity of the wire, has been determined by Underwriters Laboratories.

UL and the UL Logo are trademarks of UL LLC © 2024