APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4370 Issued:1987-02-27
Revised:2012-02-22
Style 4370 Multiple-conductor cable using non-integral jacket

Rating150 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 20 AWG solid or stranded round
InsulationExtruded SR, 7 mils minimum average thickness, 5 mils minimum thickness at any point
AssemblyTwo or more insulated conductors cabled together.
ShieldOptional
JacketExtruded SR, 15 mils minimum average thickness, 12 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment where protected from mechanical abuse, Class 2 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024