Rating | 105 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded, bare, tinned or coated. |
|
Insulation | Extruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Assembly | Two through 100 conductors, parallel construction. |
|
Shield | Metal faced PETP film or conductive thermoplastic (PVC). Conductive PVC shield, if used, may form a web between insulated conductors under the jacket. Both metal faced PETP film and extruded conductive PVC shield may be used in the same cable. |
|
Braid | Optional. |
|
Jacket | FRPVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Two laminated sheets. See facing page for compound designation.
|
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|