APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4373 Issued:1987-11-05
Revised:2008-05-27
Style 4373 Jacketed Cable

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum. Material not specified.
InsulationIrradiated XLPE, 2 mils min average, 2 mils minimum at any point.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together may belaid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketPVC
dia of cable under jacket is 0.424 inches or less30 mils min average27 mils minimum at any point
0.425-0.700 dia60 avg48 min
0.701-1.500 dia
80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.
 
UL and the UL Logo are trademarks of UL LLC © 2024