			| Rating | 105 deg C, 30 Vac, Cable flame. | 
		
			 | 
		
			| Conductor | 40 AWG minimum. Material not specified. | 
		
			 | 
		
			| Insulation | Extruded PE, 2 mils minimum average thickness, 2 mils minimum thickness at any point. | 
		
			 | 
		
			| Assembly | Two or more twisted singles or groups of twisted singles twisted together may be laid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. | 
		
			 | 
		
			| Covering | Optional - PVC, 5 mils minimum thickness at any point. | 
		
			 | 
		
			| Shield | Optional. | 
		
			 | 
		
			| Jacket | Extruded PVC | 
		
			 | Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point | 
		
			 | 0.424 inch or less | 30 mils | 27 mils | 
		
			 | 0.425 - 0.700 inch | 60 mils | 48 mils | 
		
			 | 0.701 - 1.500 inches | 80 mils | 64 mils | 
		
			 | 1.501 - 2.500 inches | 110 mils | 88 mils | 
		
			 | 2.501 inches and larger | 140 mils | 112 mils | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. | 
		
			 |