APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4382 Issued:1987-12-14
Revised:2012-04-10
Style 4382 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together may belaid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or fillers optional.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded SR
Dia of cable under jacket (inches)Minimum average (mils)Minimum at any point (mils)
0.425 or less4536
0.426-0.7006048
0.701-1.500
8064
1.501-2.50011088
2.501 and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External interconnection in Class 2 circuits of electronics equipment (such as electronic computers and business machines).