APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4383 Issued:1987-12-14
Revised:2012-04-09
Style 4383 Multiple-conductor cable using extruded non-integral jacket.

Rating60 deg C, 300 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketExtruded SR - SILICONE - See facing page for compound
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less45 mils36 mils
0.426-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.501 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection in Class 2 circuits of electronics equipment.

UL and the UL Logo are trademarks of UL LLC © 2024