APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4391 Issued:1989-02-21
Revised:2011-11-25
Style 4391 Parallel cable with extruded integral insulation and jacket

Rating125 deg C, 300 Vac, Horizontal flame.
Conductor14 AWG - 10 AWG consisting of 30 AWG or smaller stranded, tinned or bare copper.
InsulationIntegral with Jacket. EP, nominal 80 mils wall of EPDM and the following (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.109 in., Wall after rip: 0.043 in. See Facing Page for Compound Identification.
AssemblyTwo, three or four conductors, same as type SP Cord.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where ripped not more than 3 in. unless installed in a separate metal enclosure; and for use in internal wiring of remote outdoor condensing units for domestic cooling systems. Polarity identification may be omitted.