APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4396 Issued:1989-10-20
Revised:2012-07-16
Style 4396 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating75 deg C, 300 Vac, Cable Flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. May be straight or coiled in the form of a helix.
JacketExtruded Neoprene -
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of appliances or electronic equipment.