Rating | 125 deg C, voltage not specified, Horizontal flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional - The shield may be over one or more of the insulated conductors or applied between the conductor assembly and the optional covering |
|
Jacket | XLPO |
| dia of cable under jacket |
| 0.700 inches or less | 15 mils minimum average | 12 mils minimum at any point |
| 0.701-1.000 dia | 30 avg | 24 min |
| 1.000-1.500 dia | 45 avg | 36 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. |
|