APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4407 Issued:1991-08-22
Revised:2013-01-24
Style 4407 Jacketed Twin-Lead Cable

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG, solid or stranded round, tinned or bare copper.
InsulationExtruded XLPO, 15 mils min average, 13 mils minimum at any point.
JacketExtruded XLPO, 15 mils min average, 13 mils minimum at any point. Forms maximum 0.5 in. wide web.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment and Appliances.