| Rating | 125 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 32 - 10 AWG. |
|
| Insulation | Extruded XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Assembly | Two to six conductors, the form a flat ribbon cable with a web between conductors. May be used same or mixed AWG sizes. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. Tags may indicate the following: 600 Volts Peak - For Electronic Use Only. |
|