APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4413 Issued:1992-03-19
Revised:2022-09-21
Style 4413 Flat Ribbon Cable

Rating150 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded, tinned, bare or silver plated copper, or solid or stranded coated high strength copper - min 90% conductivity.
InsulationExtruded, XLPE, 15 mils minimum average thickness, 13 mils minimum thickness at any point. See facing page for compound designation.
AssemblyTwo to six conductors. All conductors in any one cable may be of the same or mixed AWG sizes. This forms a flat ribbon cable with a web between conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to movement or mechanical damage.

UL and the UL Logo are trademarks of UL LLC © 2024