Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 16 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Extruded PP, 4 mils min average at any point to 30 mils max, or Labeled or complies with manufacturer's AWM procedure. |
|
Assembly | Two to four individual conductors may be used in one cord. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Jacket | Extruded NR - NEOPRENE |
| dia of cable under jacket in inches |
| 0.425 inches or less | 24 mils min average | 19 mils minimum at any point |
| 0.426-0.700 dia | 30 avg | 24 min |
| 0.701-1.500 dia | 45 avg | 36 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring |
|