APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4416 Issued:1992-05-27
Revised:2019-11-07
Style 4416 Multiple-conductor cable using non-integral jacket

Rating125 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringExtruded, 6 mil or heavier PVC covering may be employed over the conductor assembly.
JacketEVA - See facing page for compound
dia of cable under jaceket
0.700 inches or less*45 mils min average36 mils minimum at any point
0.701-1.50 dia60 avg48 min
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of calculators, dictating machines, or X-ray equipment.

UL and the UL Logo are trademarks of UL LLC © 2024