APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4417 Issued:1992-09-24
Revised:2014-11-21
Style 4417 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating125 deg C, 600 Vac.
Conductor18 AWG - 4/0AWG, Stranded Round.
InsulationExtruded XLPE
AWG Conductor Sizemils minimum averagemils minimum at any point
18-103027
9-24540
1-4/05550
or Labeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more conductors, fillers and/or barrier tapes optional.
ShieldOptional - Braid and/or Metallic Tape.
JacketExtruded XL - See facing page for compound
dia of cable under jacket in inchesmils minimum averagemils minimum at any point
0-0.5003024
0.501-0.7504536
0.751-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial use power supply cords used in high temperature equipment.

UL and the UL Logo are trademarks of UL LLC © 2024