Rating | 200 deg C, 600 Vac. |
|
Conductor | 18 AWG - 8 AWG strands over 0.015 in stranded. |
|
Insulation | Extruded ETFE or extruded FEP or extruded PFA or extruded PTFE, TFE, See facing page for compound. |
| conductor size |
| 18-10 AWG | 15 mils min average | 13 mils minimum at any point |
| 9-8 AWG | 22 avg | 18 min |
| 6-2 AWG | 30 avg | 27 min |
| or Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more conductors |
|
Jacket | Extruded ETFE or extruded FEP or extruded PFA or extruded PTFE, TFE - See facing page for compound |
| dia of cable under jacket |
| 0-0.500 inches | 30 mils min average | 24 mils minimum at any point |
| 0.501-0.750 dia | 45 avg | 36 min |
| 0.751-1.500 dia | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | A) Special use power supply cords used in high temperature equipment.
B) Special assembly of conductors, not to exceed one meter in length, for use with portable stage lighting fixtures, in accordance with Article 520 of the NEC. |
|