APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4419 Issued:1992-12-30
Revised:2012-03-12
Style 4419 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 600 Vac, FT2 Flame.
Conductor18 AWG - 10 AWG, stranded.
InsulationExtruded Neoprene, CP, EP, NBR/PVC, SBR/NR or Thermoset CPE. 30 mils min average thickness, 27 mils minimum thickness at any point.
Assembly2 - 20 insulated conductors, same as flexible cord type SOW Cord. Mized conductor sizes may be employed.
JacketExtruded Neoprene, CP, EPDM, NBR/PVC or Thermoset CPE. 60 mils min average thickness, 48 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024