Rating | 200 deg C, 600 Vac, Cable flame. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two to sixty-one conductors, twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Jacket | Extruded SR. 2-16 conductors, 60 mils minimum average thickness, 48 mils minimum thickness at any point. 17-25 conductors, 94 mils minimum average thickness, 76 mils minimum thickness at any point. 26-61 conductors, 125 mils minimum average thickness, 100 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of high temperature appliances. |
|