Rating | 90 deg C, 600 Vac, Horizontal flame, Moisture Resistant 60 or 75 deg C (optional). |
|
Insulation | CP or CPE or EP or NBR/PVC or NR - NEOPRENE or SRB/NR or XL |
| .75 -1.0 mm conductor size | 30 mils min average | 27 mils minimum at any point |
| 1.01-6.0 mm | 45 avg | 40 min |
| 6.01-25.0 mm | 60 avg | 54 min |
|
Assembly | Same as Types S, SO, SW-A or SOW-A. |
|
Jacket | CP or EPDM or NBR/PVC or NR - NEOPRENE or SRB/NR |
| dia of cable under jacket |
| 0.500 inches or less | 80 mils min average | 64 mils minimum at any point |
| 0.501-0.750 dia | 95 avg | 76 min |
| 0.751-1.000 dia | 110 avg | 88 min |
| 1.001-1.500 dia | 125 avg | 100 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of appliances and electronic equipment outdoor and in wet locations (60 degrees or 75 degrees). |
|