Rating | 90 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 0.75 sq mm to 25 sq mm solid or stranded round. |
|
Insulation | Extruded CP or extruded CPE or extruded EP or extruded NBR/PVC or extruded NR - NEOPRENE or extruded SRB/NR or extruded XL |
| conductor size | min average | minimum at any point |
| 0.75 -1.0 mm | 30 mils | 27 mils |
| 1.01-6.0 mm | 45 mils | 40 mils |
| 6.01-25.0 mm | 60 mils | 54 mils |
|
Assembly | The cable consist of two or more conductors, same as required for Type S or SO. Mixed sizes may be employed. |
|
Jacket | Extruded CP or extruded CPE or extruded EPDM or extruded NBR/PVC or extruded NR - NEOPRENE or extruded SRB/NR |
| dia of cable under jacket | mim average | minimum at any point |
| 0.500 inches or less | 80 mils | 64 mils |
| 0.501-0.750 dia | 95 | 76 |
| 0.751-1.000 dia | 110 | 88 |
| 1.001-1.500 dia | 125 | 100 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of appliances and electronic equipment. |
|