APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4427 Issued:1993-09-20
Revised:2012-07-20
Style 4427 Multiple conductor with extruded insulation.

Rating200, 450 deg C, 600 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of 2 or more conductors twisted together. Aramid fillers and/or barrier tape optional.
ShieldOptional.
CoveringFluoroelastomer (extruded) 27 mils min at any point. See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseA) Special use power supply conductors used in high temperature stage lighting equipment. Where the acceptability of the combination will be determined by Underwriters Laboratories (such as fixtures and light bars). B) Special assembly of conductors, not to exceed one meter in length, for use with portable stage lighting fixtures, in accordance with Article 520 of the NEC.

UL and the UL Logo are trademarks of UL LLC © 2024