Style 4430 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 600 Vac, Cable flame.
Conductor26 AWG - 2 AWG solid or stranded round
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more singles, twisted pairs or groups of twisted singles twisted together. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional
JacketExtruded NBR/PVC or extruded CPE
Diameter of cable under jacketAverage thicknessMinimum thickness at any point
0.425 inch or less45 mils36 mils
0.426-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment