APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4433 Issued:1994-06-01
Revised:2011-08-15
Style 4433 Flat ribbon cable

Rating125 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 18 AWG, solid or stranded.
InsulationExtruded XLPE, 8 mils minimum average thickness, 7 mils minimum thickness at any point.
AssemblyTwo through 150 conductors laid parallel. Sections of the cable may be split into singles or groups of conductors.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment (Such as electronic computers and electric business machines).