Rating | 450 deg C insulation, 200 deg C covering, 300 Vac. |
|
Insulated Conductor | Labeled, complying with manufacturer's procedure having a minimum rating of 450 deg. C, 300 V. |
|
Assembly | Consists of 2 or more conductors twisted together. Aramid fillers and/or barrier tape optional. |
|
Covering | Extruded Fluoroelastomer, 27 mils minimum thickness at any point. See Facing Page for Compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | A) Special use power supply conductors used in high temperature stage lighting equipment. Where the acceptability of the combination will be determined by Underwriters Laboratories (such as fixtures and light bars).
B) Special assembly of conductors, not to exceed one meter in length, for use with portable stage lighting fixtures, in accordance with Article 520 of the NEC.
|
|