APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4444 Issued:1995-12-07
Revised:2011-11-09
Style 4444 Multiconductor cable with extruded non-integral jacket.

Rating80 deg C, 150 Vac, Cable flame.
Conductor18 AWG - 2 AWG, stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors laid parallel or cabled together to form a flat, oval or round cable. Conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. The use of a barrier layer and/or fillers is optional. Fillers, tape wrap, braid or extruded covering may be used.
ShieldOptional.
JacketExtruded Neoprene.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.425 inch or less45 mils36 mils
0.426-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.