APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4453 Issued:1996-07-01
Revised:2012-04-25
Style 4453 High-Voltage Flat Cable.

RatingMaximum 200 deg. C and 5 to 60 KVDC, VW-1 flame. See Facing Page for acceptable ratings.
Conductor2 or more conductors layed parallel, 24-10 AWG copper or nickel and 12-10 AWG aluminum or 27-20 AWG Resistance Wire; solid or stranded. Or Nos. 24-10 AWG solid or stranded coated high strength copper - min 90% conductivity, for 200 deg. C rating uncoated or tinned strands of copper shall be 0.015 inch or larger in diameter. Aluminum conductors shall be permitted for a 90 deg. C maximum operating temperature. Copper conductors may be tinned, silver or nickel plated, heat bonded or overcoated.
InsulationExtruded Silicone or XLFRPE. Singles bonded together or extruded. See Facing Page for material and minimum average and minimum at any point after separation requirements.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of TV receivers or where the acceptability has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024