APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4456 Issued:1996-10-04
Revised:2012-07-22
Style 4456 Multiple-conductor cable using non-integral jacket

Rating150 deg C, 30, 125 Vac, Horizontal flame.
InsulationLabeled or complying with Manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers and/or kevlar strength members are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded SR, 30 mils min average, 27 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.