APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4461 Issued:1998-02-25
Revised:2012-02-22
Style 4461 Multiple-conductor cable using non-integral jacket

Rating150, 200 deg C, 30 Vac, 125 Vac, 150 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM procedure.
AssemblyConsists of two or three singles, twisted, forming oval or round cable or parallel with optional braid and 2 or more singles cabled around the core where the lay of conductors is not specified. Manufacturer shall maintain a complete description of each assembly. May use the same or mixed AWG size.
CoveringOptional - TFE tape, PTFE tape, PFA tape or FEP tape with a minimum average thickness of 2 mils.
ShieldOptional.
FillersOptional - Polyester with minimum average diameter of 0.020 inch.
JacketExtruded SR, 30 mils minimum average thickness, 27 mils minimum thickness at any point. Shall be extruded in two layers with a monofilament or textile braid between two layers.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or internal wiring of electronic equipment or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024