APPLIANCE WIRING MATERIAL
Subj.758 Section 4 Page 4476 Issued:1999-10-29
Revised:2019-11-07
Style 4476 Multiple-conductor cable using non-integral jacket

Rating150, 200 deg C, 150, 300, 600, 1000 Vac, Construction A Horizontal flame, Construction B Cable Flame.
Conductor50 AWG - 2000 kcmil, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors, twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded Silicone
dia of cable under jacketConstruction
0.700 inches or lessconstruction A30 mils min average24 mils minimum at any point
0.700 inches or lessconstruction B45 avg36 min
0.701-1.000 diaconstruction A45 avg36 min
0.701-1.000 diaConstruction B60 avg48 min
1.001-1.500 diaconstruction A60 avg48 min
1.001-1.500 diaconstruction B80 avg64 min
1.501-2.500 diaconstruction A60 avg48 min
1.501-2.500 diaconstruction B95 avg76 min
ShieldOptional, Metal Wire Braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseConstruction A Internal wiring. Construction B External wiring.

UL and the UL Logo are trademarks of UL LLC © 2024